MKCM type AIR SIGNAL

MKCM type AIR SIGNAL               

[ Flow rate with a switch ]
  to detect the flow of fluid, it is turned ON or OFF the switch at your specified flow rate 
  ※ switch is fixed (can not be set value changes later) [ flow is visible at a glance ] transparent tube of a galvanometer to check the flow of fluid in the movement of the float [ with protective cover ] by the metal protective cover the possibility of damage due to impact or the like from the outside   and reduce. [Mounting orientation does not matter ] attitude of when mounting because it uses a spring inside is   you can do up and down and sideways, etc. freely.

 

 


 

Model List
 Model     Dimensions (mm)   Flow rate (L / min)
 Port size full length  Full width  Depth  Minimum inside diameter 
φmm
Specified range of operating flow rate maximum
MKCM20-1TA-OFF  Rc1 / 8  80 Thirty twenty two 6.5  1 to 40 300
MKCM20-1TA-ON
MKCM20-2TA-OFF Rc1 / 4 80 Thirty twenty two 6.5  1 to 40  300
MKCM20-2TA-ON
MKCM20-3TA-OFF Rc3 / 8 86 Thirty twenty five 6.5  1 to 40  300
MKCM20-3TA-ON
MKCM30-2TA-OFF Rc1 / 4 104 43 32 9.5  5 to 100  600
MKCM30-2TA-ON
MKCM30-3TA-OFF Rc3 / 8 104 43 32 9.5  5 to 100  600
MKCM30-3TA-ON
MKCM30-4TA-OFF Rc1 / 2 110 43 32 9.5  5 to 100  600
MKCM30-4TA-ON
MKCM35-4TA-OFF Rc1 / 2 124 49 44  13.5 30 to 150 1500
MKCM35-4TA-ON
MKCM35-6TA-OFF Rc3 / 4 124 49 44  13.5 30 to 150 1500
MKCM35-6TA-ON
MKCM45-6TA-OFF Rc3 / 4 142 62 Fifty 18.0 50 to 300 3000
MKCM45-6TA-ON
MKCM45-8TA-OFF Rc1 142 62 Fifty 18.0 50 to 300 3000
MKCM45-8TA-ON
       
When ordering, quote □ Please specify the inside of.
Model 
MKCM □□ - □ TA-OFF (ON)
 Operating flow rate of the switch □ L / Min
Example: MKCM20-2TA-OFF operation of the switch flow rate 30L / min
※ contact method Please specify the is OFF method or the ON system. 
 Contact is OFF (normally open · A contact) when the OFF mode, the fluid does not flow 
 contact is ON (normally closed · B contact) when it is not ON system, and fluid flow standard specification


fluid gas
Operating flow rate Above, please specify at a flow rate value within the specified range of operating flow rate.
Connection Rc female thread  Changes to the R male thread 
combination with R male thread is also available. 
Heatproof temperature Maximum 60 ℃ Heat-resistant (up to 100 ℃) are also available.
Breakdown 1MPa The breakdown voltage specification (highest 5MPa) are also available.
Maximum working voltage DC, AC 300V  
Maximum current DC, AC 0.5A  
Contact capacity 50VA  
Material
quality
Transparent tube acrylic Heat resistance and breakdown voltage specification product will be the brass tube (C3604). 
Heat resistance and breakdown voltage specification product can not be visually float.
Protective cover BC (gunmetal) Aluminum can also be manufactured.
Fittings C3604 
(brass)
Made of SUS are also available.
spring SUS304 -
Magnet containing float Acrylic or 
nylon
You may need to use the aluminum depending on the specifications.
O-ring Nitrile rubber Heat resistance and breakdown voltage specification will be the fluorine rubber.
Reed switch Commercial goods
Lead 
(standard 200mm)
Commercial goods  Designation of the length of the lead, 
it is also possible to change to the cab tire cord. 

Caution on the flow switch use
1. Notes on the magnetic impact 
 ● reed switch, since the switch acting on a magnetic, used where not affected by the magnetic field, please. 
 ● When the magnetic material of iron such as in the vicinity of the reed switch is present, it becomes the cause of the malfunction. 
2. Notes on the electrical connection 
 ● flow switch, it is an over-current flows through the reed switch in the cause, such as a ground wire connection failure as no 
  Please note the connection.
 ● Please use as much as possible the alarm detector flow switch. 
  In conjunction with other electrical equipment if you want to use and is, on the sufficient consideration of the influence of when the malfunction occurs, please handling. 
 ● use voltage, when used in suppressing the current used is as small as possible, the life of the reed switch is long Masu no longer. 
  (Usually 100V0.5A about under the circumstances 100Million times switch actuation can be used)